Power for the grid
we are building next.
One power module.
Every system.
A liquid-cooled drawer, and the skid that carries sixteen of them. Scroll to take each one apart.
CCE-PCS-150k · 750 × 825 × 230 mm · ≤ 98 kg
Power conversion system
CCE-PCS-150k
150 kW, grid-forming, liquid-cooled. Sealed in a plug-in drawer.
Everything connects at the front. DC in and AC out on plug-in connectors, with communications and status beside them. A drawer is replaced without rewiring.
Open it, and it opens up. A sealed Type 3R enclosure around three clean layers: the DC link, the power stage and the lid.
A liquid-cooled power stage. Three-level NPC phase legs share one cold plate. No dust filters, no outside air in the electronics.1
The DC link, filtered. Film capacitors, common-mode cores and the precharge board sit on their own bracket in the lower bay.1
One chassis, two ratings. The same 750 × 825 × 230 mm drawer carries 150 kW at 480 V, or 215 kW at 690 V as the CCE-PCS-215k.
CCE-MVSkid-3440 · 3440 kW · 16 × CCE-PCS-215k
Medium-voltage skid
CCE-MVSkid-3440
Sixteen modules, liquid cooling and the MV transformer. One lift.
Sealed to IP55. Each cabinet carries its own dry cooler on the roof, serving a closed liquid loop.
Everything inside, installed at the factory. Modules, cooling, controls and transformer arrive as one tested system.
Sixteen CCE-PCS-215k. Four drawers per cabinet. Every string is controlled on its own, and any one slides out from the front.
Your transformer, integrated. 3440 kVA, 6–37 kV to 0.69 kV, oil-immersed or dry-type, specified by you.2
Set on piers. Bolted down. Energised.
CCE-BMS · 3-level · BAU / BMU / CMU
Battery management system
CCE-BMS
Three levels, from every cell to the whole array.
Level 1, the CMU. At the battery module, on a daisy chain. This is where the system meets the cells.
Level 2, the BMU. It gathers its CMUs and works with the relay, the breaker and the Hall sensor.
Level 3, the BAU. The array controller: CAN down to the BMUs, CAN and RS485 to the PCS, Ethernet to the EMS.
SOC within 2.5%, SOH within 4%. Fail-safe shutdown, and security to IEC 62443 built into the controller.
Specifications
Three products.
One platform.
The same power module, chassis, cooling circuit and control firmware, from a single drawer to a 3440 kW skid.
All datasheetsCCE-PCS-150k
150kW480 V power moduleCCE-PCS-215k
215kW690 V power moduleCCE-MVSkid-3440
3440kW16 × CCE-PCS-215kElectrical
AC output
480 V, 3P3W690 V, 3P3W690 V · 6–37 kV MVDC operating range
800–1500 V1000–1500 V1000–1500 VEfficiency
Datasheet99.0 % max.99.02 % PCSOperating modes
PQ · VF · VSG · GFM, with black startMechanical
Dimensions (W × D × H)
750 × 825 × 230 mm6058 × 2438 × 2896 mm3Weight
≤ 98 kg≤ 15 tEnclosure
Type 3R · C4Type 3R / IP65 · C4IP55 / Type 3RCooling
Liquid, sealed loopEnvironment and compliance
Operating temperature
−30 to +60 °CProtocols
Modbus TCP/RTU, CANModbus, IEC 104, IEC 61850Modbus, IEC 104, IEC 61850Standards
On requestUL 1741 SB, IEEE 1547, IEEE 519UL 1741 SB, IEEE 1547, IEC 62933- Enclosure, partition, chassis, inductor housing and fasteners of the CCE-PCS-150k are shown from production CAD. Power electronics, magnetics, fans and connectors are drawn at their CAD mounting points for illustration.
- The MV transformer is customer-specified and shown as a typical oil-immersed unit.
- Datasheet dimensions, 20-ft skid. The skid shown is a production CAD arrangement of about 10.0 × 3.2 × 3.1 m.
Manufacturing
Built in the United States.
Tested before it ships.
Domestic content
Integrated under one roof, with a traceable bill of materials.
Full-power testing
Every skid is wired, filled and commissioned at the factory. The report ships with the serial number.
Engineering on the floor
Design and production share one building.
Full-power test bay
Every unit runs at rated power before it leaves the building.
Resources
The documents your engineers ask for.
Datasheets, drawings, grid-code settings and dynamic models. NDA packages within one business day.
Contact
Send us the single-line diagram.
Houston, Texas · Response within one business day